UPS maintenance and testing must be performed regularly to protect critical systems and keep them operating reliably.  Simply providing a UPS does not protect your facility from power supply fluctuations. 
Information about Preventive Maintenance (PM)
Regularly scheduled PM is required to protect your emergency power systems. (Annual, Semi-annual, or Quarterly)
Does your system require a Minor PM or a Major PM? What is the difference? Below is a short description for the tasks Power Up LLC does during each type of visit.
Regularly scheduled PM is required to protect your emergency power systems. (Annual, Semi-annual, or Quarterly)
Does your system require a Minor PM or a Major PM? What is the difference? Below is a short description for the tasks Power Up LLC does during each type of visit.
Minor PM Scope:
Visual Inspection:
Visual Inspection:
- Inspect overall unit operation
 - Inspect display function
 - Inspect alarm history
 - Inspect cooling fans
 
- Input voltages and currents
 - DC voltage and current
 - AC ripple voltage and current
 - Output voltages and currents
 - Breakers
 - Check and replace all filters (as required)
 - Perform complete thermal scan of all possible electrical connections
 - Remove all foreign debris from equipment compartments, where applicable
 - Check and record room ambient temperature and verify proper operation of ventilation equipment
 
Major PM Scope:  -Includes everything that is included in the Minor PM plus more.
Visual Inspection:
Normal and After-Hours services are available. Please call 1-888-990-9433 for pricing.
Visual Inspection:
- Inspect overall unit operation
 - Inspect display function
 - Inspect alarm history
 - Inspect cooling fans 
 - Clean and inspect all logic cards
 - Inspect all connectors
 - Inspect major components
 - Inspect cables and wiring harnesses
 - Verify that all diagnostic tests function properly
 - Verify all protection settings
 
- Input voltages and currents
 - DC voltage and current
 - AC ripple voltage and current
 - Output voltages and currents
 - Breakers
 - Check and replace all filters (as required)
 - Perform complete thermal scan of all possible electrical connections
 - Remove all foreign debris from equipment compartments, where applicable
 - Check and record room ambient temperature and verify proper operation of ventilation equipment
 - All power supply voltages
 - Check and verify manual transfers from UPS system to normal bypass and from normal bypass to UPS system
 - Check all primary and secondary circuits for proper torque
 - Check all electrical connections for proper torque and general condition
 - Check all system level alarms
 - Check power capacitors for swelling and leaking oil
 - Check and verify automatic transfers
 - Check inverter and rectifier snubbers for burned or broken wires
 